Call us at (951) 683-0930 or email us at sales@de-ice.com

Walton De-Ice
Walton De-Ice
  • Home
  • De-Ice
  • Snow Shield
  • Radome
  • Contact
  • Kymeta De-Ice System
  • Technical Field Services
  • Distributors
  • Certified Installation
  • Control and Monitoring
  • Catalog
  • Downloads
  • Events
  • Videos
  • News
  • More
    • Home
    • De-Ice
    • Snow Shield
    • Radome
    • Contact
    • Kymeta De-Ice System
    • Technical Field Services
    • Distributors
    • Certified Installation
    • Control and Monitoring
    • Catalog
    • Downloads
    • Events
    • Videos
    • News

  • Home
  • De-Ice
  • Snow Shield
  • Radome
  • Contact
  • Kymeta De-Ice System
  • Technical Field Services
  • Distributors
  • Certified Installation
  • Control and Monitoring
  • Catalog
  • Downloads
  • Events
  • Videos
  • News

Snow Shield Heaters

Electric Heaters

Heaters for 0.6 to 2.3-meter Antennas 120/220/230VAC

This heater operates on 120VAC, 220VAC or 230VAC for that includes the heater element and the blower motor. The heater will provide 1,200 Watts, 1,700 Watts, or 2,000 Watt of heat, depending on the size of the antenna and customer requirements. The heater unit utilizes brushless and maintenance free blower motors. The heater is controlled by the DS-4C Moisture/Temperature sensor. The rack mounted DP-7SS Remote Monitor/Control Panel can be added to the DS-4C.


* UL and CE Certified

Heaters for 2.4 to 3.1-meter Antennas 120/220/230 VAC

This heater uses 2 elements at 2,000 Watts each to provide 4,000 Watts of heat and utilizes brushless maintenance free blower motors. The heater is controlled by the DS-4C Moisture/Temperature sensor. The rack mounted DP-7SS Remote Monitor/ Control Panel can be added to the DS-4C. This heater requires a professionally installed electrical service.


* UL and CE Certified

Single Phase Electric Power Consumption

Heaters for 3.2 to 6.3 meter Antennas 208/220/240/380/400VAC

Using the same concepts as the two smaller heaters, this heater wattage ranges from a three element 6,000 Watt unit to a six element 12,000 Watt unit. The blower motors are brushless and maintenance free.


The heater can be controlled by the Walton Thermostat Controller or the DS-6 Local Control Unit. The Rack mounted DP-7SS Remote Monitor/Control Panel can be added to the DS-6. This heater requires a professionally installed electrical service.


* UL and CE Certified

Single Phase Electric Power Consumption

Three Phase Electric Power Consumption

Gas Heaters

Walton Gas Heater for 3.2 to 6.3-meter Antenna

The Walton Gas Heater manufactured by W.B. Walton Enterprises are designed specifically for De-icing Satellite Communication Antennas. These heaters are designed to be suspended from the antenna mounting structure and to provide long reliable service for years to come.



Dual Hot Surface Ignition System

  • Dual hot surface igniter's means redundancy in the ignition sequence.


  • Large flame sensing rod. Turbulence no longer a factor during ignition sequence.


  • Same reliable 3 try ignition sequence with purge time.


  • No more pilot assembly or pilot orifice.


  • Stainless Steel Burner greatly reducing maintenance costs and increases reliability.

Positive Blower Recognition for Ignition Sequence

  • Normally open contact on air flow switch operates power to the ignition unit. No air flow, no ignition.


  • If no airflow is verified, the ignition unit will not be energized and the unit will go into ignition failure mode.

Same Wiring and Mounting Configuration as Original Heaters

  • Older Gas Heaters can be changed out with the new designed Gas Heating Units.


  • Mounting and wiring is the same.

New Evolutions in Direct Fired Gas Heaters

Both Snow Shield Cover De-Icing Systems and the Gas Heaters for Plenum De-Icing now meet the European Union Declaration of Conformity for directives:


EN 60204-1:2006+A1:2009, EN 60529:1991+A1:2000/IEC 60529:1989+A11999 and
EN12669 (EN298:2003 EN126:2004 EN1854:2006)


EU Gas Appliance Directive Test Standards: 2009/142/EC (GAD)


EU Low Voltage Directive Test Standards: 2006/95EC


Environmental Tests: EN 60529:1991+A1:2000


W. B. Walton Enterprises, Inc. is currently applying for approvals from North American Agencies for our Gas Heating Units for both the Snow Shield Cover De-Icing System and the Plenum De-Icing Systems.

Downloads

Snow Shield Electric Heaters (pdf)Download
Snow Shield Gas Heaters Data Sheet (pdf)Download
Direct Fired Gas Heating Unit (pdf)Download
  • Home
  • De-Ice
  • Snow Shield
  • Snow Shield Heaters
  • Ice/Rain Quake
  • Radome
  • Kymeta De-Ice System
  • Technical Field Services
  • Distributors
  • Certified Installation
  • Control and Monitoring
  • ADC-3000
  • TBC-1
  • DS-4C
  • DP-7EX
  • Catalog
  • Downloads
  • Events
  • Contact
  • Videos
  • News

Walton De-Ice

4185 North Hallmark Parkway, San Bernardino, CA 92407

(951) 683-0930

Copyright © 2023 Walton De-Ice - All Rights Reserved.

Powered by GoDaddy, Developed by Ryan Rich